posted on 2024-03-05, 11:20authored byBingo Wing-Kuen Ling, Peter Kwong-Shun Tam
<p>In this paper, a lifting technique is employed to realize a single input single output linear (L,M) shift invariant plant as a filter bank system. Based on the filter bank structure, a controller is designed so that the aliasing components in the control loop are cancelled and the loop gain becomes a time invariant transfer function. Pole placement technique is applied to stabilize the overall system and ensure the causality of the filters in the controller. An example on the control of a linear (L,M) shift invariant plant with simulation result is illustrated. The result shows that our proposed algorithm is simple and effective.</p>